Cisco ASA: Apa penghitung "tx hang" di antarmuka tampilan?


12

Pertimbangkan keluaran berikut dari show interface:

Interface GigabitEthernet0/1 "inside", is up, line protocol is up
  Hardware is i82546GB rev03, BW 1000 Mbps, DLY 10 usec
    Full-Duplex(Full-duplex), 1000 Mbps(1000 Mbps)
    Input flow control is unsupported, output flow control is off
    MAC address 5057.aaaa.25d7, MTU 1500
    IP address 10.0.0.7, subnet mask 255.255.255.0
    2708954646 packets input, 1614638330819 bytes, 0 no buffer
    Received 786860 broadcasts, 0 runts, 0 giants
    7262 input errors, 7262 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
    0 pause input, 0 resume input
    0 L2 decode drops
    2622997029 packets output, 1295347863682 bytes, 6396 underruns
    0 pause output, 0 resume output
    0 output errors, 0 collisions, 90 interface resets
    0 late collisions, 0 deferred
    0 input reset drops, 7908 output reset drops, 31 tx hangs

Baris terakhir mengatakan 31 tx hangs. Apa artinya ini?


Ini pertanyaan yang sangat bagus, sampai hari ini tidak ada dalam dokumen ASA yang bisa saya temukan.
Mike Pennington

Jawaban:


5

Gantung biasanya mengacu pada transmisi bingkai ethernet yang "terlalu lama" sehingga pengontrol atau antarmuka diatur ulang. Apa yang "terlalu lama" artinya adalah sedikit misteri.


Saya tidak yakin apakah itu jawaban yang tepat, tetapi itu adalah jawaban terbaik jadi saya akan memberi Anda kredit untuk itu.
tunnelsup
Dengan menggunakan situs kami, Anda mengakui telah membaca dan memahami Kebijakan Cookie dan Kebijakan Privasi kami.